General dentistry floor plan
General Dentistry Office Floor Plan: Rooms And Sizes.
For a general practice of 2,400 sq ft, DDS.STUDIO draws 5 operatories and room for one more, a sterilization room, a pano / CBCT room, a consult room, a doctor's office, a break room, restrooms, reception and waiting. An operatory is planned at about 10 ft 6 in × 12 ft, and a patient chair needs 6.5 × 7 ft of floor with its working space.
- 10 ft 6 in × 12 ftAn operatory
- 6.5 × 7 ftA patient chair, with its clearance
- 2,400 sq ft5 chairs plus 1 to add later
What does DDS.STUDIO draw for general dentistry?
Setup describes general dentistry as "Family, restorative and hygiene". This is its starting plan in a deep bay, the shape setup starts with.
| Room | Size | Area |
|---|---|---|
| Break room | 10 × 9.5 ft | 95 sq ft |
| Consult | 11 × 9.5 ft | 105 sq ft |
| Doctor office | 10 × 10 ft | 100 sq ft |
| IT closet | 6 × 9.5 ft | 57 sq ft |
| Mechanical | 6 × 10 ft | 60 sq ft |
| Pano / CBCT | 7 × 10 ft | 70 sq ft |
| Reception | 11 × 9.5 ft | 105 sq ft |
| Restroom | 8 × 10 ft | 80 sq ft |
| Sterilization | 13 × 9.5 ft | 124 sq ft |
| Waiting | 14 × 9.5 ft | 133 sq ft |
| Future op 1 | 10 × 10 ft | 100 sq ft |
| Operatory 1 | 12 × 9.5 ft | 114 sq ft |
| Operatory 2 | 12 × 9.5 ft | 114 sq ft |
| Operatory 3 | 9 × 10 ft | 90 sq ft |
| Operatory 4 | 11 × 9.5 ft | 105 sq ft |
| Operatory 5 | 10 × 10 ft | 100 sq ft |
How much floor does each chair need?
A patient chair is 2.5 × 6 ft, and the Studio keeps 2 ft clear on each side for the doctor and the assistant. For a hygiene room, the room type "Hygiene" is planned a little narrower than an operatory.
| Chair | Footprint | Clear floor around it | Floor it needs |
|---|---|---|---|
| Patient chair | 2.5 × 6 ft | 2 ft each side, 0 ft 6 in behind, 0 ft 6 in in front | 6.5 × 7 ft |
What should you change for general dentistry?
- Hygiene rooms. Change an operatory's room type to Hygiene in the inspector; its kit still furnishes it.
- Compact operatories. Where the space is tight, the Compact operatory kit is 9 ft × 11 ft.
- Future operatories. The rooms marked "Future op" hold the space for a chair you will add later.
- Imaging. The pano / CBCT room takes a Panoramic X-ray (4 × 5 ft) or a 3D X-ray (CBCT) (5 × 5.5 ft).
What does Plan check look for?
The same advice for every specialty, from the Studio's own rules. It points things out; it never blocks a plan.
- An operatory under 70 sq ft or over 200 sq ft is pointed out; 90 to 130 sq ft is usual.
- From 4 operatories, about 12 ft of sterilization counter.
- Swing doors at least 3 ft wide, and open floor of at least 3 ft 8 in between facing walls.
- A restroom at least 5 ft each way inside, for a 5 ft turning circle.
- 1 ft clear round a compressor, a vacuum pump or a separator tank.
Other specialties
- General dentistryFamily, restorative and hygiene
- OrthodonticsOpen bay and records
- Pediatric dentistryOpen bay with a quiet room
- PeriodonticsSurgical ops and hygiene
- Oral surgerySurgical suites and recovery
- Multi-specialtySeveral providers, shared ops
These are planning values, not building code or manufacturer specifications. A plan made in DDS.STUDIO is a concept plan, not construction documents. Confirm every dimension with your architect, your equipment supplier and your local code official before you build.
How big should a general dentistry operatory be?
About 10 ft 6 in wide by 12 ft long, which is 126 sq ft. The Studio points out an operatory under 70 or over 200 sq ft. The full arithmetic is in How big should a dental operatory be?
How many operatories fit in a general practice?
The Studio suggests about one operatory for every 470 sq ft after the first 500: 4 for 2,400 sq ft.