DDS.STUDIO

General dentistry floor plan

General Dentistry Office Floor Plan: Rooms And Sizes.

For a general practice of 2,400 sq ft, DDS.STUDIO draws 5 operatories and room for one more, a sterilization room, a pano / CBCT room, a consult room, a doctor's office, a break room, restrooms, reception and waiting. An operatory is planned at about 10 ft 6 in × 12 ft, and a patient chair needs 6.5 × 7 ft of floor with its working space.

Updated

  • 10 ft 6 in × 12 ftAn operatory
  • 6.5 × 7 ftA patient chair, with its clearance
  • 2,400 sq ft5 chairs plus 1 to add later

What does DDS.STUDIO draw for general dentistry?

Setup describes general dentistry as "Family, restorative and hygiene". This is its starting plan in a deep bay, the shape setup starts with.

CONSULTOPERATORY 1OPERATORY 2OPERATORY 3PANO / CBCTRESTROOMMECHANICALOPERATORY 4STERILIZATIONIT CLOSETOPERATORY 5FUTURE OP 1DOCTOR OFFICEWAITINGRECEPTIONBREAK ROOM35'-0"
The starting plan for general dentistry. A deep bay suite of 2,400 sq ft, 35 × 68.5 ft, with 5 chairs and 1 to add later, as setup draws it in its first layout ("Halls across, waiting on the left"). Every room can be moved and resized.
Rooms in the starting plan above
RoomSizeArea
Break room10 × 9.5 ft95 sq ft
Consult11 × 9.5 ft105 sq ft
Doctor office10 × 10 ft100 sq ft
IT closet6 × 9.5 ft57 sq ft
Mechanical6 × 10 ft60 sq ft
Pano / CBCT7 × 10 ft70 sq ft
Reception11 × 9.5 ft105 sq ft
Restroom8 × 10 ft80 sq ft
Sterilization13 × 9.5 ft124 sq ft
Waiting14 × 9.5 ft133 sq ft
Future op 110 × 10 ft100 sq ft
Operatory 112 × 9.5 ft114 sq ft
Operatory 212 × 9.5 ft114 sq ft
Operatory 39 × 10 ft90 sq ft
Operatory 411 × 9.5 ft105 sq ft
Operatory 510 × 10 ft100 sq ft

How much floor does each chair need?

A patient chair is 2.5 × 6 ft, and the Studio keeps 2 ft clear on each side for the doctor and the assistant. For a hygiene room, the room type "Hygiene" is planned a little narrower than an operatory.

From the Studio's equipment catalogue
ChairFootprintClear floor around itFloor it needs
Patient chair2.5 × 6 ft2 ft each side, 0 ft 6 in behind, 0 ft 6 in in front6.5 × 7 ft

What should you change for general dentistry?

  • Hygiene rooms. Change an operatory's room type to Hygiene in the inspector; its kit still furnishes it.
  • Compact operatories. Where the space is tight, the Compact operatory kit is 9 ft × 11 ft.
  • Future operatories. The rooms marked "Future op" hold the space for a chair you will add later.
  • Imaging. The pano / CBCT room takes a Panoramic X-ray (4 × 5 ft) or a 3D X-ray (CBCT) (5 × 5.5 ft).

What does Plan check look for?

The same advice for every specialty, from the Studio's own rules. It points things out; it never blocks a plan.

  • An operatory under 70 sq ft or over 200 sq ft is pointed out; 90 to 130 sq ft is usual.
  • From 4 operatories, about 12 ft of sterilization counter.
  • Swing doors at least 3 ft wide, and open floor of at least 3 ft 8 in between facing walls.
  • A restroom at least 5 ft each way inside, for a 5 ft turning circle.
  • 1 ft clear round a compressor, a vacuum pump or a separator tank.

Other specialties

These are planning values, not building code or manufacturer specifications. A plan made in DDS.STUDIO is a concept plan, not construction documents. Confirm every dimension with your architect, your equipment supplier and your local code official before you build.

How big should a general dentistry operatory be?

About 10 ft 6 in wide by 12 ft long, which is 126 sq ft. The Studio points out an operatory under 70 or over 200 sq ft. The full arithmetic is in How big should a dental operatory be?

How many operatories fit in a general practice?

The Studio suggests about one operatory for every 470 sq ft after the first 500: 4 for 2,400 sq ft.