DDS.STUDIO

Multi-specialty floor plan

Multi-Specialty Dental Office Floor Plan: Shared Operatories.

For a multi-specialty practice, DDS.STUDIO starts from 5 operatories and one to add later in 2,400 sq ft, then each room takes the chair its provider uses. The catalogue has four: a patient chair needs 6.5 × 7 ft of floor with its working space, an orthodontic chair 5 × 6.5 ft, a pediatric bench 5.5 × 6 ft and a surgical chair 8 × 8.5 ft.

Updated

  • 4 kinds of chairPatient, orthodontic, pediatric, surgical
  • 8 × 8.5 ftThe largest: a surgical chair
  • 2,400 sq ft5 chairs plus 1 to add later

What does DDS.STUDIO draw for multi-specialty?

Setup describes multi-specialty as "Several providers, shared ops". This is its starting plan in an office suite.

OPERATORY 1OPERATORY 2OPERATORY 3STERILIZATIONPANO / CBCTMECHANICALCONSULTOPERATORY 4OPERATORY 5FUTURE OP 1IT CLOSETWAITINGRECEPTIONRESTROOMDOCTOR OFFICEBREAK ROOM57'-0"
The starting plan for multi-specialty. A office suite suite of 2,400 sq ft, 57 × 42 ft, with 5 chairs and 1 to add later, as setup draws it in its first layout ("Halls across, waiting on the left"). Every room can be moved and resized.
Rooms in the starting plan above
RoomSizeArea
Break room11 × 10.5 ft116 sq ft
Consult11 × 11 ft121 sq ft
Doctor office10 × 10.5 ft105 sq ft
IT closet7 × 11 ft77 sq ft
Mechanical7 × 10.5 ft74 sq ft
Pano / CBCT7 × 10.5 ft74 sq ft
Reception12 × 10.5 ft126 sq ft
Restroom8 × 10.5 ft84 sq ft
Sterilization13 × 10.5 ft137 sq ft
Waiting16 × 10.5 ft168 sq ft
Future op 111 × 11 ft121 sq ft
Operatory 110 × 10.5 ft105 sq ft
Operatory 210 × 10.5 ft105 sq ft
Operatory 310 × 10.5 ft105 sq ft
Operatory 411 × 11 ft121 sq ft
Operatory 512 × 11 ft132 sq ft

How much floor does each chair need?

Size each operatory for the largest chair it will ever take: a room that may hold a surgical chair needs its width from the start.

From the Studio's equipment catalogue
ChairFootprintClear floor around itFloor it needs
Patient chair2.5 × 6 ft2 ft each side, 0 ft 6 in behind, 0 ft 6 in in front6.5 × 7 ft
Orthodontic chair2 × 5.5 ft1 ft 6 in each side, 0 ft 6 in behind, 0 ft 6 in in front5 × 6.5 ft
Pediatric bench2.5 × 5 ft1 ft 6 in each side, 0 ft 6 in behind, 0 ft 6 in in front5.5 × 6 ft
Surgical chair3 × 6.5 ft2 ft 6 in each side, 1 ft behind, 1 ft in front8 × 8.5 ft

What should you change for multi-specialty?

  • Mix the chairs. Swap each room's chair, from Chairs in the Equipment tab, for the provider who uses it.
  • Shared support rooms. One sterilization room serves every operatory; from 4 operatories, plan about 12 ft of counter.
  • Future operatories. Rooms marked "Future op" hold space for a provider who joins later.
  • Imaging. One pano / CBCT room is shared: a 3D X-ray (CBCT) is 5 × 5.5 ft.

What does Plan check look for?

The same advice for every specialty, from the Studio's own rules. It points things out; it never blocks a plan.

  • An operatory under 70 sq ft or over 200 sq ft is pointed out; 90 to 130 sq ft is usual.
  • From 4 operatories, about 12 ft of sterilization counter.
  • Swing doors at least 3 ft wide, and open floor of at least 3 ft 8 in between facing walls.
  • A restroom at least 5 ft each way inside, for a 5 ft turning circle.
  • 1 ft clear round a compressor, a vacuum pump or a separator tank.

Other specialties

These are planning values, not building code or manufacturer specifications. A plan made in DDS.STUDIO is a concept plan, not construction documents. Confirm every dimension with your architect, your equipment supplier and your local code official before you build.

How do I plan operatories for several specialties?

Size each room for the largest chair it may hold, then place the chair its provider uses. DDS.STUDIO checks each room against the chair in it.

Can one sterilization room serve a multi-specialty practice?

In DDS.STUDIO's plans, yes: one sterilization room serves every operatory, with about 12 ft of counter from 4 operatories.