Multi-specialty floor plan
Multi-Specialty Dental Office Floor Plan: Shared Operatories.
For a multi-specialty practice, DDS.STUDIO starts from 5 operatories and one to add later in 2,400 sq ft, then each room takes the chair its provider uses. The catalogue has four: a patient chair needs 6.5 × 7 ft of floor with its working space, an orthodontic chair 5 × 6.5 ft, a pediatric bench 5.5 × 6 ft and a surgical chair 8 × 8.5 ft.
- 4 kinds of chairPatient, orthodontic, pediatric, surgical
- 8 × 8.5 ftThe largest: a surgical chair
- 2,400 sq ft5 chairs plus 1 to add later
What does DDS.STUDIO draw for multi-specialty?
Setup describes multi-specialty as "Several providers, shared ops". This is its starting plan in an office suite.
| Room | Size | Area |
|---|---|---|
| Break room | 11 × 10.5 ft | 116 sq ft |
| Consult | 11 × 11 ft | 121 sq ft |
| Doctor office | 10 × 10.5 ft | 105 sq ft |
| IT closet | 7 × 11 ft | 77 sq ft |
| Mechanical | 7 × 10.5 ft | 74 sq ft |
| Pano / CBCT | 7 × 10.5 ft | 74 sq ft |
| Reception | 12 × 10.5 ft | 126 sq ft |
| Restroom | 8 × 10.5 ft | 84 sq ft |
| Sterilization | 13 × 10.5 ft | 137 sq ft |
| Waiting | 16 × 10.5 ft | 168 sq ft |
| Future op 1 | 11 × 11 ft | 121 sq ft |
| Operatory 1 | 10 × 10.5 ft | 105 sq ft |
| Operatory 2 | 10 × 10.5 ft | 105 sq ft |
| Operatory 3 | 10 × 10.5 ft | 105 sq ft |
| Operatory 4 | 11 × 11 ft | 121 sq ft |
| Operatory 5 | 12 × 11 ft | 132 sq ft |
How much floor does each chair need?
Size each operatory for the largest chair it will ever take: a room that may hold a surgical chair needs its width from the start.
| Chair | Footprint | Clear floor around it | Floor it needs |
|---|---|---|---|
| Patient chair | 2.5 × 6 ft | 2 ft each side, 0 ft 6 in behind, 0 ft 6 in in front | 6.5 × 7 ft |
| Orthodontic chair | 2 × 5.5 ft | 1 ft 6 in each side, 0 ft 6 in behind, 0 ft 6 in in front | 5 × 6.5 ft |
| Pediatric bench | 2.5 × 5 ft | 1 ft 6 in each side, 0 ft 6 in behind, 0 ft 6 in in front | 5.5 × 6 ft |
| Surgical chair | 3 × 6.5 ft | 2 ft 6 in each side, 1 ft behind, 1 ft in front | 8 × 8.5 ft |
What should you change for multi-specialty?
- Mix the chairs. Swap each room's chair, from Chairs in the Equipment tab, for the provider who uses it.
- Shared support rooms. One sterilization room serves every operatory; from 4 operatories, plan about 12 ft of counter.
- Future operatories. Rooms marked "Future op" hold space for a provider who joins later.
- Imaging. One pano / CBCT room is shared: a 3D X-ray (CBCT) is 5 × 5.5 ft.
What does Plan check look for?
The same advice for every specialty, from the Studio's own rules. It points things out; it never blocks a plan.
- An operatory under 70 sq ft or over 200 sq ft is pointed out; 90 to 130 sq ft is usual.
- From 4 operatories, about 12 ft of sterilization counter.
- Swing doors at least 3 ft wide, and open floor of at least 3 ft 8 in between facing walls.
- A restroom at least 5 ft each way inside, for a 5 ft turning circle.
- 1 ft clear round a compressor, a vacuum pump or a separator tank.
Other specialties
- General dentistryFamily, restorative and hygiene
- OrthodonticsOpen bay and records
- Pediatric dentistryOpen bay with a quiet room
- PeriodonticsSurgical ops and hygiene
- Oral surgerySurgical suites and recovery
- Multi-specialtySeveral providers, shared ops
These are planning values, not building code or manufacturer specifications. A plan made in DDS.STUDIO is a concept plan, not construction documents. Confirm every dimension with your architect, your equipment supplier and your local code official before you build.
How do I plan operatories for several specialties?
Size each room for the largest chair it may hold, then place the chair its provider uses. DDS.STUDIO checks each room against the chair in it.
Can one sterilization room serve a multi-specialty practice?
In DDS.STUDIO's plans, yes: one sterilization room serves every operatory, with about 12 ft of counter from 4 operatories.