Periodontics floor plan
Periodontal Office Floor Plan: Surgical Operatories And Hygiene.
For a periodontal practice of 2,400 sq ft, DDS.STUDIO draws 5 operatories and one to add later, with sterilization, imaging and consult. A surgical chair is 3 × 6.5 ft and needs 8 × 8.5 ft of floor with 2 ft 6 in clear each side, so a surgical operatory wants more width than the 10 ft 6 in a general one is planned at.
- 8 × 8.5 ftA surgical chair, with its clearance
- 2 ft 6 inClear on each side of it
- 2,400 sq ft5 chairs plus 1 to add later
What does DDS.STUDIO draw for periodontics?
Setup describes periodontics as "Surgical ops and hygiene". This is its starting plan in an L-shaped suite.
| Room | Size | Area |
|---|---|---|
| Break room | 10 × 13 ft | 130 sq ft |
| Consult | 10.5 × 12 ft | 126 sq ft |
| Doctor office | 12.5 × 9 ft | 113 sq ft |
| IT closet | 12 × 7 ft | 84 sq ft |
| Mechanical | 12.5 × 6 ft | 75 sq ft |
| Pano / CBCT | 12.5 × 6 ft | 75 sq ft |
| Reception | 12 × 13 ft | 156 sq ft |
| Restroom | 8 × 13 ft | 104 sq ft |
| Sterilization | 12 × 15 ft | 180 sq ft |
| Waiting | 15 × 13 ft | 195 sq ft |
| Future op 1 | 12.5 × 10 ft | 125 sq ft |
| Operatory 1 | 12 × 11 ft | 132 sq ft |
| Operatory 2 | 10.5 × 12 ft | 126 sq ft |
| Operatory 3 | 12.5 × 9 ft | 113 sq ft |
| Operatory 4 | 12 × 11 ft | 132 sq ft |
| Operatory 5 | 12.5 × 9 ft | 113 sq ft |
How much floor does each chair need?
The surgical chair needs more room on every side than a patient chair. Plan surgical operatories wider, and keep hygiene rooms at the usual size.
| Chair | Footprint | Clear floor around it | Floor it needs |
|---|---|---|---|
| Surgical chair | 3 × 6.5 ft | 2 ft 6 in each side, 1 ft behind, 1 ft in front | 8 × 8.5 ft |
| Patient chair | 2.5 × 6 ft | 2 ft each side, 0 ft 6 in behind, 0 ft 6 in in front | 6.5 × 7 ft |
What should you change for periodontics?
- Surgical operatories. Widen the rooms that will take a surgical chair, and swap the chair, from Chairs in the Equipment tab.
- Surgery and sedation equipment. The catalogue has a Nitrous cart, a Patient monitor, an Implant motor cart and a Microscope (each 1.5 × 1.5 ft or 2 × 2 ft), and an Emergency cart (2 × 1.5 ft).
- Gases. A N₂O / O₂ manifold (2.5 × 1.5 ft) goes in the mechanical room.
- Hygiene. Change some operatories to the room type Hygiene.
What does Plan check look for?
The same advice for every specialty, from the Studio's own rules. It points things out; it never blocks a plan.
- An operatory under 70 sq ft or over 200 sq ft is pointed out; 90 to 130 sq ft is usual.
- From 4 operatories, about 12 ft of sterilization counter.
- Swing doors at least 3 ft wide, and open floor of at least 3 ft 8 in between facing walls.
- A restroom at least 5 ft each way inside, for a 5 ft turning circle.
- 1 ft clear round a compressor, a vacuum pump or a separator tank.
Other specialties
- General dentistryFamily, restorative and hygiene
- OrthodonticsOpen bay and records
- Pediatric dentistryOpen bay with a quiet room
- PeriodonticsSurgical ops and hygiene
- Oral surgerySurgical suites and recovery
- Multi-specialtySeveral providers, shared ops
These are planning values, not building code or manufacturer specifications. A plan made in DDS.STUDIO is a concept plan, not construction documents. Confirm every dimension with your architect, your equipment supplier and your local code official before you build.
How big should a periodontal surgical operatory be?
Wide enough for a surgical chair and 2 ft 6 in each side: in DDS.STUDIO's catalogue that is 8 × 8.5 ft for the chair and its clearance, before cabinets.
Does DDS.STUDIO include sedation equipment?
Yes, generic and unbranded: a nitrous cart, a patient monitor, an emergency cart and a N₂O / O₂ manifold for the mechanical room.